Non-Negative Pressure Water Supply Equipment

Post a Purchase Request

Seven Major Advantages

    1. No pollution: There is no reservoir or storage tank; water runs in a fully sealed system from the inlet, with no secondary pollution at all. 2. Low investment: No reservoir or storage tank needs to be built, and no frequent cleaning or disinfection is required, saving more than 50% of construction costs and later cleaning and maintenance costs.

3. Small footprint: No reservoir or storage tank needs to be built, so the system takes up little space. The space saved can even be used for parking, generating extra income.

 4. Energy saving: Makes full use of municipal network pressure, adding only as much pressure as is missing. When supply pressure meets requirements, the system stays idle; when supply pressure is insufficient, it starts automatically. Saves 20%-80% energy compared with traditional water supply equipment.

5. Stable water pressure: Sensors monitor outlet pressure in real time, and variable-frequency control keeps outlet pressure constant. 6. Easy installation: The system leaves the factory complete and compact, and simply connects to the inlet and outlet pipes, so the construction period is short.

7. Easy management: Fully automatic operation, with protection against overload, short circuit, overcurrent and water shortage, plus automatic reset.

 Product Features

   1. Lower investment: Saves about 50% of investment. No reservoir or rooftop tank needs to be built; pressure-superimposed supply reduces initial equipment investment.

2. High efficiency, energy saving and low operating cost: Makes full use of municipal network pressure, adding only as much as is missing, without creating negative pressure. Saves 30%-90% energy compared with traditional water supply equipment. Water can still be supplied at municipal network pressure during power outages.

 3. Highly intelligent, simple to operate, labor-saving: The equipment is controlled by a fully automatic intelligent controller that adjusts itself to users' water consumption and mains pressure, enabling unattended operation. A human-machine interface (text and digital) lets customers see the equipment's operating status at a glance.

4. Clean and hygienic: Fully sealed operation eliminates secondary pollution of the water source.

 5. Comprehensive protection: Automatic protection against overload, short circuit, overvoltage, undervoltage, phase loss, overcurrent and water source shortage. Under abnormal conditions it provides signal alarms, self-checks and fault diagnosis.

 6. Small footprint, easy installation: The complete system consists of only three parts: a water supply control cabinet, a non-negative pressure steady-flow tank and a pump set, making installation very simple.

7. Longer equipment life: Reliable soft start for multiple pump sets prevents shocks to the power grid and pipe network, and the pumps run in rotation, greatly extending the life of pumps and motors. Equipment life can be extended more than threefold.

 Core Technology

 Core Technology 1: Fully automatic intelligent pressure-superimposed regulation: In addition to the flow stabilization and pre-pressure compensation provided by a vacuum suppressor and negative pressure eliminator, this technology uses a proprietary process design to boost and regulate the mains water, achievingby borrowing network pressure, true triple boosting and pressure superimposition for energy saving and lower consumption. It also processes information: data is collected in real time, analyzed and computed by the system, and sent to the corresponding actuators.

Core Technology 2: Fully automatic intelligent under-pressure regulation: When mains pressure is insufficient, the fully automatic intelligent under-pressure regulation system adjusts at any time according to network conditions (including pressure, water level feedback, flow and pressure regulation) to keep the equipment supplying water normally and meet demand at the least favorable point of the network. Core Technology 3: Fully sealed pressurized steady-flow compensation: Conventional pressure superimposition eliminates negative pressure through contact with the atmosphere, whereas this system uses fully sealed components that meet drinking water requirements, so drinking water never contacts any gas, strictly ensuring its hygiene and safety. As pressure-bearing equipment, it always runs under pressure in all conditions, fundamentally eliminating the possibility of negative pressure in the network. Technical Specifications

 1. Flow rate: 0-1500 m³/h, head.

2. Controlled motor power: 0.75-1500 kW.

 3. Households served: 10-10,000.

  4. Pressure control range: 0.15-1.6 MPa.

  5. Average power saving: 30-60%.

 6. Control principle: sine-wave PWM or space vector SVPWM.

  7. Operating mode: automatic switching between single or multiple pumps.

8. Control mode: programmable and PID control.

9. Overload capacity: 150% for 60 seconds.

10. Protection: soft start, with self-diagnostic display and protection against overvoltage, phase loss, phase change, undervoltage, open circuit, momentary power failure, short circuit, etc.

  Equipment Advantages

   1. High efficiency and energy saving: The working pressure is set according to users' water demand, and the system automatically adjusts pump speed and the number of pumps in operation based on that setting, achieving stepless regulation from zero to full flow so that the system always runs in its most energy-efficient state: more supply when more is used, less supply when less is used, and shutdown when nothing is used. Saves 20%-80% energy compared with traditional water supply equipment.

 2. Stable water pressure: Sensors monitor outlet pressure in real time, and variable-frequency control keeps outlet pressure constant.

 3. Easy installation: The equipment leaves the factory as a complete, compact set and simply connects to the tank outlet and the building inlet, so the construction period is short.

 4. Fully automatic operation: Simple to operate and fully automatic, with soft start and soft stop that cause no shocks to the pipe network or power grid, extending the life of all components and the system.

 5. Comprehensive protection: Protection against overcurrent, overload, overheating, overvoltage, undervoltage, short circuit, phase loss, water shortage, locked rotor, etc. The system also provides self-checking, fault diagnosis, fault memory, fault display, automatic fault handling, automatic start of the standby pump and isolation of faulty pumps.

Unattended operation

Post a Purchase Request

Items marked with "*" are required

Contact Us

Address: Liujin Road, Sitaizi Industrial Park, Bayuquan District, Yingkou, Liaoning, China

Contact: Mr. Li Chuanyi +86 138 4076 5457

Technical Service: Mr. Song (Engineer) +86 183 0417 8511

Factory Tel: 0417-2267160

E-Mail: 113329659@qq.com
xygs66888@163.com

Xiyuan