How to Choose a Drainage Pump — From an Integrated Pump Station Manufacturer
Sewage pumps used inside buildings include submersible sewage pumps, submerged drainage pumps, vertical sewage pumps and horizontal sewage pumps. Vertical and horizontal sewage pumps require vibration-isolated foundations and take up space, so they are rarely used in buildings.
Inside buildings where space is limited and drainage volume is small, submersible sewage pumps and submerged sewage pumps are preferred. Submerged sewage pumps can be used in more important locations: they are compact, small, quiet, easy to move and simple to install, with significant energy savings and easy maintenance. No pump room is needed; they simply sit in the water, greatly reducing project costs.
In public buildings, each sump should be treated as a unit with one standby pump, and the pumps should normally run alternately to reduce prolonged loading and extend their service life.
Integrated pump station experts say that when pumping wastewater containing large solids, the discharge pipes of submersible sewage pumps in different sumps should not be combined, and the pumps should ideally have a grinding device. When lifting sewage with a lot of fibrous material, submersible sewage pumps with cutters or large passages can be used.
When two or more pumps share one discharge pipe, a valve and a check valve should be fitted on each pump's discharge pipe. Where a single pump's discharge may cause backflow, a check valve should be installed. Pressure drainage pipes must not be combined with gravity drainage pipes inside the building.
1.Economically, the lowest total cost of equipment, operation, maintenance and management should be considered as a whole.
2.Mechanically, high reliability, low noise and low vibration.
3. The selected model and performance meet the process requirements for flow, head, pressure, temperature, NPSH, suction lift and other parameters.
4. Must meet the requirements of the medium's properties.
● For pumps conveying corrosive media, wetted parts must be made of corrosion-resistant materials, e.g. fluoroplastic pumps; if the medium is only mildly corrosive, engineering plastic pumps may be used as appropriate.
●For pumps conveying flammable, explosive, toxic or valuable media, a reliable shaft seal or a leak-free pump is required, such as a magnetic drive pump, diaphragm pump or canned motor pump.For pumps conveying media containing solid particles,
●wetted parts must be made of corrosion- and wear-resistant materials, and if necessary the shaft seal should be flushed with clean liquid.