Composition and Working Principle of Integrated Pump Stations

     An integrated pump station is a single unit made up of a top cover, GRP shaft, submersible pumps, service platform, piping, electrical controls, ventilation system and other parts. It is pre-assembled and tested before leaving the factory, and its function is to lift stormwater and sewage for the subsequent treatment process.
    Integrated pump stations are usually installed partway along a drainage network where the pipe is deeply buried and the water must be lifted to a higher downstream network, or at the end of a drainage network.
When flow from the drainage network enters the integrated pump station, it first passes through a grinder screen that cuts up large solids; the reduced particles then enter the station's sump, which contains various sensing devices, pumps and piping.
     As the water level changes, a pressure sensor or float sends the station's level information back to the control system, which switches the pumps on and off according to its set operating parameters.
When the level reaches the set pump start level, the control system starts the pumps, and sewage is pumped from the station to the municipal sewer outlet;
when the sewage level falls below the set level, the system stops the pumps. This cycle repeats, keeping the integrated prefabricated pump station running smoothly.