How to Choose an Integrated Sewage Pump Station

How to choose an integrated sewage lift pump station: as technology advances, the drawbacks of traditional concrete pump stations have become increasingly apparent, and concrete pump stations can no longer
meet people's needs. GRP integrated prefabricated pump stations have come into view. By comparison, integrated pump stations occupy less land, do not pollute the water, make no noise, need no bottom cleaning and last a long time, so they are popular with customers. So how do you choose an integrated pump station? Today I'll explain.

Since the pump is the heart of an integrated pump station, you need to choose the pump before choosing the station. Flow is one of a pump's most important performance parameters, as it determines how much water is handled. When se
lecting a pump, the flow is usually taken as 1.1 times the normal flow. Next is head: the pump model is generally chosen using the maximum head plus a 5%-10% margin.
Integrated pump stations also have requirements regarding terrain and landform. They must comply with relevant national regulations, and the Code for Design of Pump Stations can be followed.
Stations should be placed on natural ground with firm soil and rock and favorable geological conditions, avoiding poor ground such as soft soil, loose sand and expansive soil. They should not be located in zones with active fault structures.
Integrated pump stations can be used for municipal sewage discharge; the medium discharged directly determines the materials chosen for the prefabricated station's shell and pumps. Generally, the content of flammable and
explosive gases, the content of corrosive media, and the viscosity and density of the medium must be considered. All of these must be taken into account during selection to choose the right pump and shell ma
More... terials.
The effective volume of an integrated pump station is related to the size of the pumps. So determine the flow, then the number and model of pumps, and you can
determine the effective volume of your pump station.