Formulas for Calculating the Maximum and Minimum Liquid Levels of Integrated Pump Stations

Installation Rules for Integrated Pump Stations


1. The layout of prefabricated integrated pump stations shall comply with the following:

 

(1) Meet the requirements for configuration, installation, operation and maintenance of the station's electromechanical equipment.

 

(2) Meet structural configuration requirements.

 

(3) Meet transport requirements.

 

(4) Environmentally sound layout in harmony with the surroundings.

 

2. The elevation of the station's base slab shall be determined by the pump installation elevation, flow channel layout and pipe installation requirements, together with the site's topography and geology. Auxiliary equipment, electrical equipment, piping and cables around the station shall be arranged to avoid interference.

 

3. Pumps in prefabricated integrated pump stations shall use auto-coupling wet installation; the pump room and inlet well shall be integrated in the same shaft, with an internal maintenance platform and an above-ground control panel.

 

4. The design of integrated pump stations shall consider the results of combined sewage discharge and the environmental impact of station failures.

 

5. The structural design of integrated pump stations shall consider anti-flotation capacity, soil chemistry and possible differential settlement relative to other installations.

 

2. Design of Integrated Pump Stations

 

1. The type of integrated pump station shall be chosen according to its geographical location, conditions and other factors.

 

2. The station site must have transport access and lifting facilities.

 

3. The design of integrated pump stations shall be determined by comparing options based on the local construction plan and the scale of water supply and drainage works.

 

4. An appropriate project scale shall be determined in line with near-term planning and principles.

 

3. The layout of integrated pump stations shall comply with the following:

 

(1) For dry-installed pumps, the plan layout shall consider pump installation and flow in the pump suction pipes; with three-pump sets and air-cooled motors, the plan layout shall also meet the pumps' heat dissipation requirements.

 

(2) The plan dimensions and layout of the station shall accommodate the pumps, screens and other main equipment.

 

(3) The plan dimensions of the wet well must meet the requirements for flow conditions in the pump suction pipes and for setting, lifting and daily operation of the screens.

 

(4) The plan dimensions of the dry well shall meet the requirements for installation, heat dissipation, maintenance and daily operation of the pumps and control cabinet.

 

(5) Modular integrated pump stations shall have a sump and drainage pump in the dry well to remove standing water.

 

(6) The control cabinet may be placed in the dry well or above ground; if placed in the dry well, ventilation, heat dissipation and dehumidification must be considered.

 

(7) Where multiple shafts are combined, the plan layout shall meet the requirements for installing and operating the station as a whole, and the same pump model shall be used in each shaft.

 

(8) Station design shall cover the structural form and materials, equipment selection, plan layout, vertical layout, and instrumentation, electrical and control equipment of the integrated pump station.

 

(9) Pumps shall be selected to meet flow requirements, and a uniform pump model shall be used.

 

(10) Wet-installed submersible pumps shall have a motor cooling system; dry-installed pumps may use water-cooled or air-cooled motors rated IP54 or higher.

 

(11) Where pumps stop automatically under level control, the effective volume between the maximum and minimum levels in the sump shall be determined by the maximum number of pump stops per hour, and can be calculated with the following formula:

 

VEff — effective volume of the integrated pump station (m³)

 

qp — pumping flow of the largest single pump in the station (m³/h)

 

Zmax — maximum number of pump starts and stops per hour.

 

When estimating from the sump inflow and each pump's pumping pattern, the effective volume can be calculated with formula (5.2.12-2)

 

Vmin=TminQ/4(5.2.12-2)

 

where Vmin — minimum effective sump volume (m³)

 

Tmin — minimum pump operating cycle (s)

 

q — pump flow (m³/s)